Direct answer

In one three-year randomized trial, posterior three-unit implant bridges made of monolithic zirconia showed no chipping, while porcelain-fused-to-metal bridges chipped in 3 of 23 patients examined at three years (13%). Both bridge types had high survival and stable gum and bone measurements. The chipping difference was not statistically significant, so this study suggests, but does not prove, a lower chipping risk. [1]

Key takeaways

  • Observed chipping at three years: 0 of 22 monolithic zirconia bridges versus 3 of 23 porcelain-fused-to-metal bridges (13%). [1]
  • The difference was not statistically significant (p = 0.11); the trial was small and event numbers were low. [1]
  • Both bridge types showed high survival, comparable complication-free survival, and stable bone levels over three years. [1]
  • The study tested bridge materials on titanium implants. It does not evaluate ceramic (zirconia) implants. [1]
  • Monolithic zirconia has no separate veneering-porcelain layer, which is the layer that chipped in the metal-ceramic group. [1]

What are monolithic zirconia and porcelain-fused-to-metal bridges?

An implant-supported bridge (in research, an implant-supported fixed dental prosthesis) is a fixed row of connected replacement teeth held by dental implants. In this trial, each bridge replaced three back teeth and was supported by two implants.

A monolithic zirconia bridge is milled from a single block of zirconia, a tooth-colored ceramic, and has no separate layer of veneering porcelain. A porcelain-fused-to-metal (PFM) bridge, also called a metal-ceramic bridge, has a metal framework covered by a layer of veneering porcelain that provides the tooth-colored surface.

Chipping means a small fracture of the veneering porcelain. Chipping usually does not cause the bridge to be lost, but it may require polishing, repair, or replacement. For background on terminology, see whether zirconia is the same as porcelain.

How was the three-year zirconia bridge trial designed?

Pachiou and colleagues at the University of Zurich conducted a prospective randomized controlled trial, published in Clinical Oral Implants Research in 2026. A randomized trial assigns treatments by chance, which reduces selection bias when comparing two options. [1]

  • Patients: 55 partially edentulous adults received a bridge (28 monolithic zirconia, 27 PFM); 45 were examined at three years (22 zirconia, 23 PFM). [1]
  • Restoration: a screw-retained three-unit bridge in the upper or lower back teeth, supported by one premolar implant and one molar implant. [1]
  • Implants: titanium–zirconium (Roxolid) implants from one manufacturer. The zirconia bridges were bonded to titanium bases; the PFM bridges used cast high-noble gold-alloy abutments veneered with feldspathic porcelain. [1]
  • Primary outcome: ceramic fracture (chipping). Secondary outcomes included bridge survival, complications, gum measurements, and marginal bone levels. [1]
  • Excluded: heavy smokers (more than 15 cigarettes daily), patients with poor oral hygiene, and pregnant patients. [1]

What did the trial find after three years?

Three-year outcomes of posterior three-unit implant bridges, by bridge material
OutcomeMonolithic zirconiaPorcelain-fused-to-metalStatistically significant difference?
Porcelain chipping (patients examined at 3 years)0 of 22 (0%)3 of 23 (13%)No (p = 0.11)
Bridge failures1 (caused by implant loss)1 (caused by implant loss)No (p = 1.00)
All recorded complications47No (p = 0.40)
Marginal bone level changeStableStableNo
Clinically acceptable rating (USPHS criteria)All bridgesAll bridgesNo

Source: Pachiou and colleagues, 2026. [1] The 13% figure counts patients examined at three years. Counting all 27 PFM bridges placed at the start, the same three events correspond to 11.1%. Two chipping events occurred in the first year and one between the first and third years. [1]

Minor occlusal (chewing-surface) wear was rated in 5 of 23 PFM bridges and 1 of 21 zirconia bridges at three years, also without a statistically significant difference. Plaque and bleeding on probing increased in both groups over time, while probing depth and bone levels stayed stable; the authors suggest that hygiene-related factors rather than the bridge material may explain the increase. [1]

Why might monolithic zirconia chip less?

In a PFM bridge, the veneering porcelain and the junction between porcelain and framework are recognized weak points under chewing forces, especially in back teeth. Systematic reviews identify veneering-porcelain chipping as the most common technical complication of layered implant bridges. [1] [2]

A monolithic zirconia bridge has no veneering layer to chip. The trial authors attribute the absence of chipping in the zirconia group to the elimination of this layer. [1] Monolithic zirconia is not unbreakable: like any restoration, it can wear the opposing teeth, fracture under unfavorable conditions, or require adjustment, and multi-unit monolithic designs have less long-term clinical data than PFM. [1] [2]

What are the limitations of this evidence?

  • Not statistically significant: with 45 patients at three years and only three chipping events, the trial could not rule out chance as an explanation for the observed difference. [1]
  • Medium-term follow-up: three years is shorter than the expected service life of an implant bridge. Longer follow-up of this trial is needed to show whether the pattern persists. [1]
  • One setting, one system: experienced university clinicians, one implant manufacturer, one zirconia material, and a standardized screw-retained design. Results may differ with other materials, abutments, or bridge lengths. [1]
  • Titanium implants: the trial compared bridge materials on titanium–zirconium implants. It provides no direct evidence about ceramic implants or fully metal-free restorations. [1]
  • Selected patients: heavy smokers and patients with poor hygiene were excluded, and smoking was not systematically recorded. Assessors could not be blinded because the materials look different. [1]
  • Funding: the ITI Foundation funded the study and the implant manufacturer supplied materials; two authors reported reimbursed lectures or consulting for that manufacturer. [1]

How is an implant bridge material chosen?

No single bridge material is best for every patient. The trial supports both monolithic zirconia and PFM as reasonable options for posterior three-unit implant bridges in selected patients. [1] Factors that usually influence the choice include:

  • Bite forces and habits such as clenching or grinding (see teeth grinding and implant risk).
  • The location of the bridge and how visible it is.
  • Appearance, color, and translucency goals.
  • The available vertical and horizontal space for the restoration.
  • Oral hygiene and the ability to clean around the bridge.
  • Repair options and long-term maintenance.
  • The patient’s individual goals, preferences, and medical history.

At the Ceramic Dental Implant Centre, restoration recommendations are based on a comprehensive evaluation of each patient’s oral health, functional requirements, and esthetic preferences. Learn more about the final crown or bridge and whether ceramic implants can support a bridge.

What this means for patients

If you are planning a fixed bridge on implants in the back of the mouth, this trial is encouraging early evidence that a monolithic zirconia bridge may avoid the porcelain chipping that sometimes occurs with metal-ceramic bridges. Both options performed well for three years, so the observed chipping difference is one consideration among several, not a reason by itself to choose a material. [1]

A zirconia bridge does not make the whole restoration metal-free when it sits on titanium implants or titanium bases, as it did in this trial. See whether a zirconia implant means the entire restoration is metal-free. Any bridge requires home care and regular professional maintenance; see maintaining and cleaning implants.

Questions to ask your implant clinician

  • Which bridge materials are suitable for my bite, space, and the location of the missing teeth?
  • Will my bridge have a veneering-porcelain layer, or is it monolithic?
  • What are the implant, abutment, and screw made of?
  • How would chipping, wear, or fracture be repaired with each option?
  • Does my grinding or clenching change the recommended material or design?
  • Is the bridge screw-retained or cemented, and how will it be maintained?

Article authorship and update information

Organizational author: Ceramic Dental Implant Institute. Responsible organization: Ceramic Dental Implant Centre.

Published: October 21, 2026. This article summarizes one published randomized trial and is not a systematic review. Conclusions may change as longer follow-up becomes available.

For source corrections or questions about the review process, see the corrections and content updates policy and clinical review process.

Selected references

  1. Pachiou A, Singh R, Jung RE, Balmer M, Benic GI, Ioannidis A. Monolithic Zirconia Versus Porcelain-Fused-to-Metal Implant-Supported Fixed Dental Prostheses in the Posterior Region: 3-Year Results of a Randomized Controlled Clinical Trial. Clinical Oral Implants Research. 2026;37(10):1197–1207. doi:10.1111/clr.70160. PMID: 42629625. Open-access full text. Trial registration DRKS00011039.
  2. Sailer I, Strasding M, Valente NA, Zwahlen M, Liu S, Pjetursson BE. A systematic review of the survival and complication rates of zirconia-ceramic and metal-ceramic multiple-unit fixed dental prostheses. Clinical Oral Implants Research. 2018;29(Suppl 16):184–198. doi:10.1111/clr.13277. PMID: 30328185.

Google Preferred Sources

Make our guides easier to find

Add Ceramic Dental Implant Centre as a preferred source so Google can highlight our educational guides when they are relevant to your searches.